INSTALL INTEGRATED LOWER CONTROL ACTUATOR (ILCA) CHECK VALVE
(AVIM)
(Continued)
7-94
Acetone (E20) is flammable and toxic.
It can irritate skin and cause burns.
Use only in well-ventilated area, away
from heat and open flame. In case
of contact, immediately flush skin
or eyes with water for at least 15
minutes. Get medical attention for
eyes.
NOTE
Procedure is same to install No. 1
or No. 2 check valve on roll, pitch,
or yaw actuator. Installation of No. 1
valve is shown here.
1.
Clean sealant from area of port (1). Use acetone
(E20) and cloths (E135). Wear goggles and
gloves (E186).
2.
Install two packings (2 and 3) on check valve (4).
3.
Install valve (4) in port (1). Torque valve to 17
inch-pounds.
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin
and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
4.
Apply bead of sealant (E336) around valve (4).
Wear goggles and gloves (E186).
5.
Lockwire check valve (4) to relief valve (5). Use
lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Test ILCA (Task 7-98).
END OF TASK