TM 55-1520-240-23-6
7-67
INSTALL POWER TRANSFER UNIT FLOW LIMITER
(Continued)
7-67
6.
Connect two tubes (11) to tee (10).
7.
Remove lockwire from plug (12). Remove plug
(12) and packing (13) from port (14).
8.
Fill motor (15) through port (14) with hydraulic
fluid (E199). Use hand oiler. Use cloths (E135)
for spilled fluid.
9.
Install plug (12) and packing (13) in port (14).
10.
Lockwire plug (12) to housing (16). Use lockwire
(E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Service reservoir (Task 1-60, 1-61, or 1-62).
Bleed utility hydraulic system (Task 7-334).
Perform operational check (TM 55-1520-240-T).
Close right forward work platform or pylon access
doors (Task 2-2),
END OF TASK