TM 55-1520-240-23-6
7-69
REMOVE AND INSPECT POWER TRANSFER UNIT PUMP SHAFT SEAL
(590974)
(Continued)
7-69
7.
Remove retainer clip (11), ring (12), and shim
(13) from shaft (14). Use retaining ring pliers.
NOTE
Make sure pin does not drop out when
removing mating ring.
8.
Remove mating ring (15). Use needle nose
pliers.
9.
Remove pin (16).
10.
Remove packing (17) from mating ring (15).
11.
Remove rod (6) from shaft (14).
12.
Remove pump (1) from vise (2).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-304