TM 55-1520-240-23-6
7-67
INSTALL POWER TRANSFER UNIT FLOW LIMITER
(Continued)
7-67
NOTE
Procedure is same to install flow
limiter in No. 1 or No. 2 unit. No. 1
unit is shown here.
1.
Install packing (1), two retainers (2), and packing
(3) on limiter (4).
2.
Install limiter (4) in FLOW LIMITER port (5).
Torque limiter to 850 inch-pounds.
3.
Lockwire limiter (4) to housing (6). Use lockwire
(E231).
4.
Connect tube (7) to tee (8) and tube (9). Remove
tag.
5.
Install tee (10) in limiter (4).