TM 55-1520-240-23-6
7-65
INSTALL POWER TRANSFER UNIT PILOT VALVE
(Continued)
7-65
NOTE
Procedure is same to install pilot valve
in No. 1 or No. 2 unit. No. 1 unit is
shown here.
1.
Install two retainers (1), packing (2), four
retainers (3), and two packings (4) on valve (5).
2.
Install valve (5) in SOL PLT VALVE port (6).
Torque valve to 60 inch-pounds.
3.
Connect connector (7) to valve (5).
4.
Lockwire valve (5) to housing (8). Use lockwire
(E231).
7-293