TM 55-1520-240-23-6
7-64
REMOVE POWER TRANSFER UNIT PILOT VALVE
(Continued)
7-64
NOTE
Procedure is same to remove pilot
valve in No. 1 or No. 2 unit. No. 1
unit is shown here.
1.
Disconnect connector (1) from valve (2). Use
gloves (E186).
2.
Remove lockwire from valve (2).
3.
Remove valve (2), six retainers (3), and three
packings (4) from housing (5).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-291