TM 55-1520-240-23-6
7-49.1
ASSEMBLE ACCUMULATOR (AD-A620-1D340)(AVIM)
7-49.1
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Wrench, 3/4 Inch Open End
Torque Wrench, 0 to 100 Foot-Pounds
Source of Low Pressure Compressed Air
Soft Jawed Vise
Goggles
Materials:
Dry Cleaning Solvent (E162)
Hydraulic Fluid (E199)
Cloth (E120)
Gloves (E186)
Parts:
Packings
Retainer Rings
Personnel Required:
Aircraft Pneudraulics Repairer (2)
Inspector
References:
TM 55-1520-240-23P
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1.
Clean all parts (1 thru 3) with dry cleaning solvent
(E162). Dry with low pressure compressed air.
Use goggles for eyes. Use gloves (E186).