TM 55-1520-240-23-6
7-20
TEST FILL MODULE (AVIM)
7-20
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Container, 2 Quart
Vise
Hose, 1/4 Inch, 0 psi
Hydraulic Test Stand
Support Fixture (APP E-31)
Stopwatch
Graduate, 10 cc (2)
Graduate, 500 cc
Dial Indicating Scale, 0 to 50 Pounds
Relief Valve
Shutoff Valve (5)
Restrictor Valve (2)
Gage, 500 psi (2)
Tube, 1/4 Inch, 0 to 500 psi
Bleed Fitting, 1/4 Inch
Materials:
Hydraulic Fluid (E199)
Cloths (E120)
Gloves (E186)
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
References:
Task 7-19
Equipment Condition:
Off Helicopter Task
Fill Module Installed In Crashproof Box
Test Setup
General Safety Instructions:
Use suitable crashproof box to shield
personnel and equipment in case of
failure during test.
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-146