TM 55-1520-240-23-5
6-181.2
INSPECT AND REPAIR COMBINING TRANSMISSION OIL COOLER FAN EXHAUST
DUCT
(Continued)
6-181.2
INSTALL DUCT ASSEMBLY
Oil (E254) is toxic. It can irritate skin
and cause burns. Avoid inhaling. Use
only with adequate ventilation. Avoid
contact with skin, eyes, or clothing.
In case of contact, immediately flush
skin or eyes for at least 15 minutes.
Get medical attention for eyes.
13.
Coat thread of clamp (1) with oil (E254). Install
clamp (1) around bottom of duct assembly (2).
14.
Install duct assembly on fan (3). Torque clamp to
35 inch-pounds.
FOLLOW-ON MAINTENANCE:
Close pylon hinged fairing (Task 2-2).
END OF TASK
6-595