TM 55-1520-240-23-56-97INSTALL AFT TRANSMISSION(Continued)6-97NOTEOil hoses are reached throughgenerator access holes on each sideof pylon.23.Connect two oil hoses (56 and 57) to reducers(58 and 59) on top of transmission (1).NOTEConnect wires to left and rightgenerator in same way. Connectionsare reached through access holes oneach side of pylon.24.Connect electrical connector (60) to generator.Connect four wires (61) to generator with nuts(62). Install cover plate (63) with two screws (64).REMOVE HOIST KIT25.Working from cabin, disconnect cables (9) offorward hoist (15) from two forward lifting lugs(10) on transmission (1). Working from side ofpylon, disconnect cables of aft hoist from two aftlifting lugs (11) on transmission (1).26.Have helpers operate two hoists (15) to raisecables (9).6-371