TM 55-1520-240-23-4
5-93
INSTALL SHOCK ABSORBER (Continued)
5-93
INSTALL ABSORBER (WITHOUT 50 OR WITH 58 )
WARNING
Antiseize compound (E75) can form
toxic vapors if exposed to flame.
Use in well-ventilated area, away
from open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
3.
Coat inside diameter of two bushings (9 and 9.1),
the shank of bolts (3 and 4), and sliding bushing
(5). Use a very light coat of antiseize compound
(E75). Wear gloves (E186).
4.
Have inspector verify that sliding bushing (5)
is correctly installed in lower inboard lug (10).
Install if necessary.
INSTALL ABSORBER (WITH 50 )
4.1.
Coat inside diameter of two bushings (5 and
5.1), the shank of bolts (3 and 4), and bushings
(9 and 9.1). With a very light coat of antiseize
compound (E75). Wear gloves (E186).
4.2.
Have inspector verify that bushings (5 and 5.1)
are installed in lower inboard lug (10).
4.3.
Have inspector verify that bushing (9) does not
protrude above or below and is tight in upper lug
(10). Use straight across surfaces of lug.
5-559