TM 55-1520-240-23-4
5-93
INSTALL SHOCK ABSORBER
(Continued)
5-93
NOTE
Procedure is same to install any
shock absorber. There are six shock
absorbers.
1.
Clean bearing bores (1) of shock absorber (2).
Use cloth (E120).
INSTALL ABSORBER WITHOUT 50 OR WITH 58
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
2.
Clean bolts (3 and 4), bushing (5), and washers
(6, 7, and 8). Use cloth (E120) damp with solvent
(E162). Wear gloves (E186).
INSTALL ABSORBER WITH 50
2.1.
Measure bushing (8.1) of bolt (4) at several
places. Use a micrometer. Minimum diameter of
bushing shall be 1.090 inch.
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
2.2.
Clean bolts (3 and 4) and washer (7). Use cloth
(E120) damp with acetone (E20). Wear gloves
(E186).
5-558