TM 55-1520-240-23-3
4-11
DISASSEMBLE POWERPLANT
(Continued)
4-11
21.
Disconnect hose (67) at tee (68). Tag and
remove hose.
22.
Disconnect and remove tee (68) from two hoses
(69). Tag, disconnect, and remove two hoses
from powerplant (70).
NOTE
Engine mount adapters and aft mount
link must not be removed if powerplant
is to be stored on adapter.
23.
If powerplant (70) is to be stored on adapter (71)
go to Follow-On Maintenance. If powerplant is to
be stored in container, go to step 24.
24.
Install sling (72) as follows:
a.
Connect two cables (73) to forward fittings
(74) on powerplant (70).
b.
Connect cable (75) into aft fitting (76) on
powerplant (70).
c.
Adjust sling (72) until eye (77) is over aft hole
(78) in sling bar (79).
d.
Install pin (80) through bar (79).
4-65