TM 55-1520-240-23-3
4-11
DISASSEMBLE POWERPLANT
(Continued)
4-11
29.
Remove lockwire from eights bolts (90). Remove
eight bolts and washers (91) and remove two
adapters (87).
30.
Remove bolt (92), two washers (93), bushing
(94), and nut (95) from adapter (96). Remove
link (86) and spacer (97).
31.
Remove lockwire and bolt (98) and remove
adapter (96).
NOTE
Ensure that the N2 RPM limiting
stop is removed from fuel control
(TM 55-2840-254-23).
32.
Prepare powerplant (70) for storage container
(99) (TM 55-2840-254-23).
33.
Lower powerplant (70) into storage container
(99).
4-67