TM 55-1520-240-23-3
3-85
INSTALL AFT BRAKE (Continued)
3-85
WARNING
Antiseize compound (E75) can form
toxic vapors if exposed to flame.
Use in well-ventilated area, away
from open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
CAUTION
Use only high-shear bolts for this
installation.
NOTE
The axle flange has eight bolt holes
but only six are used.
4.
Apply antiseize compound (E75) to shanks of six
shear bolts (5). Install six bolts (5), 12 washers
(6), and six nuts (7). Wear gloves (E184.1).
5.
Torque six nuts (7) to 190 inch-pounds.
NOTE
If a new brake is being installed,
perform step 6. If not, go to step 7.
6.
Install nut (8), washer (9), packing (10), and tee
(11) with cap (12) in brake (2). Tighten nut.
7.
Connect tube (4) to tee (11).
3-220