TM 55-1520-240-23-10
16-59.14 AN/ALE-47 PAYLOAD MODULE LOADING (Continued)
16-59.14
NOTE
For flare types M206 and M212, skip
steps 5 thru 8.
For flare type M211, skip steps 9 and
10.
NOTE
String is used to allow air trapped
in squib cup to be released during
installation of impulse cartridge.
Strings are attached to underside of
PA19 Ammo Can lid.
5.
Put one end of string (8) into flare cartridge (5)
squib cup.
6.
Insert one impulse cartridge (7) into each squib
cup and install using thumb pressure.
7.
Holding impulse cartridge in place, slowly pull
string (8) out of squib cup. Ensure impulse
cartridge (7) is not pulled from squib cup as
string is pulled out.
8.
If impulse cartridge is not seated properly,
remove and repeat steps 5 thru 7.
16-250.28
Change 1