TM 55-1520-240-23-10
16-6
INSPECT CENTER CARGO HOOK PARTS AVIM
(Continued)
16-6
24.
Check two electrical switches (25) for continuity.
Use multimeter.
25.
Check plug connector (26) and electrical cable
(27) for fraying.
26.
Check emergency release cable (28) for fraying.
27.
Inspect hook (29) for cracks and distortion. If a
crack in the cargo hook is suspected, refer to
TM 1-1520-253-23.
28.
Measure diameter of two lugs (30). Diameter
shall not be less than 0.990 inch.
NOTE
Access door (33) is removed with 35 .
29.
Check guard (31), two covers (32), and access
door (33) for cracks and for elongated or
damaged screw holes.
30.
Measure diameter of four holes (34) in guard
(31). Diameter shall not be more than 0.288
inch.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
16-50