TM 55-1520-240-23-10
14-2
CLEAN AND INSPECT WINCH CABLE
(Continued)
14-2
1.
Reel out cable (1) (TM 55-1520-240-T). Have
helper keep slight pull on cable as cable reels
out.
2.
Shut down electrical and hydraulic power.
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
3.
Wet cloth (E135) with solvent (E162) and wipe
cable (1) clean. Wear gloves (E186).
4.
If any of the following conditions are found, have
the cable replaced (Tasks 14-10 and 14-11).
NOTE
A strand is seven wires twisted
together. A cable has 19 strands.
a.
Check cable (1) for broken strands by passing
clean dry cloth (E135) along cable. (Refer to
TM 1-1500-204-23.)
b.
Check cable (1). There shall be no bends,
kinks, corrosion, or crushed wires. Inspect for
20 feet of red paint on both ends of cable.
c.
Check outer wires for wear. If wear on outer
wires is 40 to 50 percent, replace cable (TM
1-1500-204-23).
d.
Check cable ball end (2). Ball end shall not
be loose.
5.
Apply electrical and hydraulic power.
6.
Reel in cable (1) (TM 55-1520-240-T). Have
helper keep slight drag on cable as cable is
reeled in.
7.
Shut down electrical and hydraulic power.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
14-9