TM  55-1520-240-23-9 11-98 INSTALL  ROLL IDLER  BELLCRANK 11-98 INITIAL  SETUP Applicable  Configurations: All Tools: Aircraft  Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Torque  Wrench,  0  to  150  Inch-Pounds Dial Indicating  Scale,  0  to  10  Pounds Materials: Cleaning  Cloth  (E120) Dry  Cleaning  Solvent  (E162) Epoxy  Primer  (E292) Gloves  (E184.1) Parts: Cotter  Pins Personnel  Required: Medium  Helicopter  Repairer Inspector References: TM  1-1520-253-23 TM  55-1520-240-23P Task  1-13 General  Safety Instructions: Epoxy  primer  (E292)  is  flammable and  toxic.   It  can  irritate  skin  and cause  burns.  Use  only  with  adequate ventilation,  away  from  heat  and open  flame.  Avoid  contact  with  skin, eyes,  or  clothing.  In  case  of  contact, immediately  flush  skin  or  eyes  with water  for  at  least  15 minutes.   Get medical  attention  for  eyes. Dry  cleaning  solvent  (E162)  is combustible  and  toxic.   Avoid  contact with  skin,  eyes,  or  clothing.   Use only  with  adequate  ventilation,  away from  open  flame.   In  case  of  contact, immediately  flush  skin  or  eyes  with water  for  at  least  15 minutes.   Get medical  attention  for  eyes. 11-512