TM 55-1520-240-23-9
11-225
INSTALL AFT LCT CONNECTING LINK
11-225
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 100 to 750 Inch-Pounds
Torque Wrench, 700 to 1600 Inch-Pounds
Materials:
Antiseize Compound (E75)
Cable Straps (E375)
Lockwire (E231)
Gloves (E184.1)
Parts:
Cotter Pins
Washers
Personnel Required:
Medium Helicopter Repairer (2)
Inspector
References:
TM 55-1520-240-23P
Task 1-13
Task 11-222
General Safety Instructions:
Antiseize compound (E75) can form
toxic vapors if exposed to flame. Use
only with adequate ventilation, away
from open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Bushings must be in swashplate and
yoke before installing bolts; otherwise,
damage to components will result.
11-876