TM 55-1520-240-23-9
11-212
REMOVE FORWARD LCT YOKE
(Continued)
11-212
Dry cleaning solvent (E162) is
combustible and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
Do not use cadmium plated hardware
or tools while working on yoke
assembly. Titanium yoke could be
damaged.
NOTE
If general cleaning is required before
disassembly, use solvent (E162), cloth
(E120), gloves (E186).
Positive retention bolts are installed in
upper controls. Bolts have pawl which
prevents nut or bolt removal unless
pawl is depressed (Task 1-13).
Attaching bolts, washers and nuts will
be temporarily installed after removing
components.
1.
Disconnect actuator connector (1) from
receptacle (2).
2.
Cut and remove five cable clamps (3) holding
connecting link cable (4) to yoke (5),
3.
Remove cotter pins (6), nuts (7), and washers
(8).
4.
Support yoke (5) and remove bolts (9) and
washers (10) attaching connecting link (11) and
actuator (12) to yoke.
5.
Lower yoke (5).
6.
Loosely install bolts (9), washers (8 and 10), and
nuts (7) in lugs of yoke (5).
11-840