TM 55-1520-240-23-9
11-178.1
REPAIR YAW, THRUST, ROLL, OR PITCH ILCA INTERMEDIATE CONNECTING LINKS
(AVIM)
11-178.1
INITIAL SETUP
Applicable Configurations:
All
Tools:
Machine Shop Set, NSN 4920-00-405-9279
Arbor Press
Roller Staking Kit (T169)
Materials:
Crocus Cloth (E122)
Epoxy Primer (E292)
Epoxy Primer (E292.1)
Gloves (E184.1)
Kevlar Gloves (E187)
Acetone (E20)
Carbon Dioxide (Dry Ice) (E92)
Methanol (E243)
Cloth (E120)
Parts:
Bearings
Sleeve
Personnel Required:
Machinist
Inspector
References:
TM 1-1520-253-23
TM 55-1500-322-24
TM 55-1520-240-23P
MIL-I-6866
Task 11-8
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Acetone (E20) is extremely flammable.
It can be toxic. Avoid inhaling. Use
only with adequate ventilation. Avoid
contact with skin, eyes, or clothing.
Keep away from heat, sparks, or open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
Carbon dioxide (dry ice) (E92) is
toxic. It can irritate skin and causes
burns. Avoid inhaling. Use only with
adequate ventilation. Avoid contact
with skin, eyes, or clothing. In case
of contact, immediately flush skin
or eyes with water for at least 15
minutes. Get medical attention for
eyes.
Methanol (E243) is flammable and
toxic. Use only with adequate
ventilation. Keep away from heat and
open flame. Do not inhale. Do not
contact eyes, skin, or clothing. In
case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
Carbon dioxide (dry ice) (E92) in
methanol (E243) has temperature of
-120ºF (-84ºC). Observe all safety
measures when working with dry
ice (E92) and methanol (E243), and
when handling chilled parts. Avoid
breathing carbon dioxide vapor.
Wear protective Kevlar gloves (E187)
when handling chilled bearings.
Epoxy primer (E292 or E292.1) is
flammable and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from heat
or open flame. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
11-708