TM 55-1520-240-23-9
11-272
BENCH TEST AFCS CONTROL PANEL (AVIM)
(Continued)
11-272
93.
Set CONTINUITY TEST UNITS switch (21) to 9.
94.
Set and hold CYCLIC TRIM FWD switch (27)
to RET. CONTINUITY TEST, lamp (22) shall be
off. Release switch.
95.
Set CONTINUITY TEST UNITS switch (21) to 0.
96.
Set CONTINUITY TEST TENS switch (20) to 10.
97.
Set and hold CYCLIC TRIM AFT switch (28) to
RET. CONTINUITY TEST, lamp (22) shall be off.
Release switch.
98.
Set CONTINUITY TEST TENS switch (20) to 00.
99.
Set CONTINUITY TEST UNITS switch (21) to 7.
100.
Set and hold CYCLIC TRIM FWD switch (27) to
EXT. CONTINUITY TEST, lamp (22) shall be off.
Release switch. Lamp (22) shall be off.
101.
Set CONTINUITY TEST UNITS switch (21) to 8.
102.
Set and hold CYCLIC TRIM AFT switch (28) to
EXT. CONTINUITY TEST, lamp (22) shall be off.
Release switch. Lamp (22) shall be off.
END CYCLIC TRIM AUTOMATIC TEST
11-1046