TM 55-1520-240-23-9
11-272
BENCH TEST AFCS CONTROL PANEL (AVIM)
(Continued)
11-272
74.
Set CONTINUITY TEST UNITS switch (21) to 9.
Lamp (22) shall be off.
75.
Set and hold CYCLIC TRIM FWD switch (27) to
RET. CONTINUITY TEST, lamp (22) shall be on.
Release switch. Lamp shall be off.
76.
Set CONTINUITY TEST TENS switch (20) to 10.
77.
Set CONTINUITY TEST UNITS switch (22) to 0.
78.
Set and hold CYCLIC TRIM AFT switch (28) to
RET. CONTINUITY TEST. Lamp (22) shall be on.
Release switch. Lamp (22) shall be off.
79.
Set CONTINUITY TEST UNITS switch (21) to 1.
Lamp (22) shall be on.
80.
Set CONTINUITY TEST UNITS switch (21) to 2.
Lamp (22) shall be off.
81.
Set CONTINUITY TEST UNITS switch (21) to 3.
Lamp (22) shall be off.
82.
Set CONTINUITY TEST UNITS switch (21) to 4.
Lamp (22) shall be off.
83.
Set CONTINUITY TEST UNITS switch (21) to 5.
Lamp (22) shall be off.
END CYCLIC TRIM MANUAL TEST