TM 55-1520-240-23-7
9-84
INSTALL FORWARD FORMATION LIGHTS
9-84
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
Twine (E433)
Insulation Sleeving (E204)
Cloths (E120)
Acetone (E20)
Sealant (E336)
Gloves (E186)
Parts:
Electrical Connectors
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for at last
15 minutes. Get medical attention
for eyes.
1.
Clean sealant from top of housing (1). Use
acetone (E20) and cloths (E120). Wear gloves
(E186).
2.
Remove tape from ends of two wires (2).
3.
Cut two sleeves (3) about 1.5 inches long. Slide
on two wires (4) of light (5). Use sleeving (E204).
4.
Connect wires (4) to wires (2) with connectors
(6). Remove tags.
5.
Slide sleeves (3) over connectors (6). Tie ends
of sleeves. Use twine (E433).
INSPECT
9-276