TM 55-1520-240-23-7
9-85.2
INSTALL NVG FORMATION LIGHT
9-85.2
INITIAL SETUP
Applicable Configurations:
With 17
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
Insulating Sleeving (E204)
Cloths (E120)
Twine (E433)
Acetone (E20)
Sealant (E336)
Gloves (E186)
Parts:
Wire Splices
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
Acetone (E20) is extremely flammable.
It can be toxic. Avoid inhaling. Use
only with adequate ventilation. Avoid
contact with skin, eyes, or clothing.
Keep away from heat, sparks, or open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
1.
Clean sealant from skin around doubler (1). Use
acetone (E20) and cloths (E120). Wear gloves
(E186).
2.
Remove tape from ends of two wires (2). Cut two
sleeves (3) about 1.5 inches long. Slide onto
two wires (4) of light (5). Use sleeving (E204).
3.
Connect wires (4) to wires (2) with connectors
(6). Remove tags.
4.
Slide sleeves (3) over connectors (6). Tie ends
of sleeves. Use twine (E433).
9-281