TM 55-1520-240-23-7
9-52
INSTALL APU GENERATOR CONTACTOR
(Continued)
9-52
NOTE
Procedure is same for removal of
APU Generator Contactor from No.
1 or No. 2 power distribution panel.
Removal of APU Generator Contactor
from No. 2 power distribution panel is
shown here.
1.
Position generator contactor (1). Install four bolts
(2) and washers (3).
2.
Connect electrical connector (4).
3.
Remove tape and connect 12 wires (5) by
installing 9 washers (6) and nuts (7). Remove
tags.
4.
Position contactor cover (8). Install two screws
(9) and washers (10).
INSPECT
5.
Close panel (11). Tighten six fasteners (12).
FOLLOW-ON MAINTENANCE:
Perform operational check of generators (TM
55-1520-240-T).
END OF TASK
9-153