TM 55-1520-240-23-7
9-52.1
REPLACE APU GENERATOR SLAVE RELAY
(Continued)
9-52.1
1.
Open No. 2 power distribution panel (PDP) (1).
2.
Remove eight screws (2) and washers (3). Tag
and remove eight wires (4). Use tags (E264).
Tape ends of wires. Use tape (E385).
3.
Remove two screws (5) and washers (6).
Remove generator slave relay (7).
9-155