TM 55-1520-240-23-7
9-50
INSTALL NO. 2 GENERATOR CONTACTOR
(Continued)
9-50
NOTE
Procedure is same for installation of
generator contact in No. 1 or No. 2
power distribution panel. Installation
of contactor in No. 2 power distribution
panel is shown here.
1.
Position generator contactor (1). Install four bolts
(2) and washers (3).
2.
Connect electrical connector (4).
3.
Remove tape and connect wires (5) by installing
washers (6) and nuts (7). Remove tags.
4.
Position contactor cover (8). Install two washers
(9) and screws (10).
5.
Close panel (11). Tighten six fasteners (12).
FOLLOW-ON MAINTENANCE:
Perform operational check of generators (TM
55-1520-240-T).
END OF TASK