TM 55-1520-240-23-7
9-38
INSTALL EXTERNAL POWER MONITOR
9-38
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
None
Personnel Required:
Aircraft Electrician
Inspector
References:
TM 55-1520-240-23P
1.
Position external power monitor (1), receptacle
(2) forward, on unboard panel (3) of electrical
compartment upper forward side.
2.
Install four screws (4) and washers (5) in monitor
(1).
3.
Connect connector (6) to receptacle (2) of
monitor (1).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check of electrical system (TM
55-1520-240-T).
Close left forward access cover of electrical
compartment (Task 2-2).
END OF TASK
9-120