TM 55-1520-240-23-7
9-36
INSTALL GENERATOR CONTROL PANEL
(Continued)
9-36
NOTE
Procedure is same to install No. 1
or No. 2 generator control panel.
Installation of No. 1 is shown here.
1.
Position panel (1) on brackets (2). Install four
screws (3) and washers (4).
2.
Connect electrical connector (5) to receptacle (6).
3.
Connect wire (7) on stud (8). Tighten nut (9).
INSPECT
FOLLOW-ON MAINTENANCE:
Close left or right electrical compartment access door
(Task 2-2).
Perform operational check of ac power system (TM
55-1520-240-T).
END OF TASK