TM 55-1520-240-23-78-43 TEST FORWARD OR AFT CYCLIC TRIM INDICATOR 8-43INITIAL SETUPApplicable Configurations:AllTools:Electrical Repairer’s Tool Kit, NSN 5180-00-323-4915AC Power Supply, 115 Volt 60 HzMeter Test Set, TS-682A/GSM-1Wire, No. 20, InsulatedConnector, MS3476W10-6SMaterials:NonePersonnel Required:Aircraft ElectricianInspectorReferences:TM 11-6625-277-14Equipment Condition:Off Helicopter TaskElectrical Test Setup1. Connect forward or aft cyclic trim indicator (1) totest setup (TM 11-6625-277-14).2. Turn on power supply (2).3. Adjust test set (3) for minimum dc output.4. Turn on test set (2).5. Adjust test set dc output. Increase dc output untilindicator (1) reads full scale (test indication dot).6. Check test set (2). Test set shall read 520 to 530microamperes.7. Adjust test set (3) to minimum dc output.8. Shut down test set (2) (TM 11-6625-277-14).9. Shut down power supply (3).10. Remove indicator (1) from test setup.FOLLOW-ON MAINTENANCE:NoneEND OF TASK8-129