TM 55-1520-240-23-6
7-124
REMOVE FORWARD PIVOTING SERVOCYLINDER
(Continued)
7-124
1.
Have helper in passageway, tag and disconnect
two hoses (1) from tees (2). Use container and
cloths (E135) for spilled fluid. Use gloves (E186).
2.
From work platform, tag and disconnect two
hoses (3) from servocylinder (4). Use container
and cloths (E135) for spilled fluid.
Support weight of swashplate lug prior
to removing upper mount bolt from
servocylinder. Damage to mounts
and/or servocylinder may result if item
is dropped.
Positive retention bolts are installed in
the upper controls. They have a pawl
which prevents nut or bolt removal
unless the pawl is depressed.
3.
Remove cotter pin (5), nut (6), washer (7), and
bolt (8) from lug (9).
7-555