TM 55-1520-240-23-6
7-123.3
REMOVE PIVOTING OR SWIVELING SERVOCYLINDER PRESSURE (JAM) INDICATOR
7-123.3
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
Cleaning Cloths (E120)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Equipment Condition:
Forward and Aft Work Platforms Open (Task 2-2)
Servocylinder Safety Blocks Installed (Task 11-28)
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Hydraulic System Depressurized (Task 1-63)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-550