TM 55-1520-240-23-6
7-101
ADJUST EXTENSIBLE LINK SELF FEEDBACK TRANSDUCER (AVIM) (Continued)
7-101
NOTE
Perform steps 5 thru 9 only if a large
adjustment of the SELF FEEDBACK
transducer is required.
5.
Set test power switch (1) to OFF.
NOTE
Deleted.
6.
Tag and disconnect four wires (24, 25, 26, and
27) from pins 1, 2, 3, and 4 of receptacle (28)
of extensible link (29).
7.
Connect four wires (24, 25, 26, and 27) to
terminals (30, 31, 32, and 33) of test adapter
(34). Match wire colors with colors marked on
adapter.
8.
Connect cable 145GS278-5 (35) between
receptacle (36) of adapter (34) and SAS 1
receptacle (37) of electrical unit.
9.
Set POWER switch (1) to ON.
10.
Turn transducer (21) until DVM (39) indicates
NULL.
11.
Hold transducer (21) and move lockrings (20 and
23) together. Release transducer.
12.
Hand tighten retainer (19).
13.
Check DVM (39). Reading shall not exceed
0.018 volts. If greater than 0.018 volts, repeat
steps 4 thru 13.
14.
Torque retainer (19) to 85 inch-pounds. Use
1-1/4 inch crowfoot.
Change 1
7-483