TM 55-1520-240-23-6
7-101
ADJUST EXTENSIBLE LINK SELF FEEDBACK TRANSDUCER (AVIM) (Continued)
7-101
NOTE
For a No. 2 extensible link installed
on an actuator, use SAS 2 test set
controls.
1.
Set electrical unit controls as follows:
a.
Power switch (1) to ON.
b.
Both FUNCTION SELECT switches (2 and 3)
to CLSD LOOP.
c.
Both FEEDBACK SELECT switches (4 and
5) to SELF.
d.
Both VALVE CONTROLS (6 and 7) to NULL.
e.
Both SQ WAVE controls (8 and 9) to
MINIMUM.
f.
Both LINK TEST switches (10 and 11) to
SELF FDBK.
g.
Both EXTERNAL METER SELECT switches
(12 and 13) to SELF FDBK.
h.
BITE switch (14) to -20V.
i.
SYSTEM SELECT switch (15) to SAS 1.
j.
SOLENOID SHUTOFF switch (16) to CLOSE.
k.
CYCLE MOTOR switch (17) to OFF.
l.
LAMP TEST switch (18) to released (out).
2.
Remove lockwire from retainer (19) and lockring
(20) from transducer (21).
3.
Cut strap (22). Remove strap.
4.
Turn retainer (19) counterclockwise until lockring
(20) can be parted from lockring (23). Keep
lockrings apart.