TM 55-1520-240-23-67-98 TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR(ILCA) (AVIM) (Continued)7-98TEST 4EXTENSIBLE LINK CROSS FEEDBACKTRANSDUCER NULL VOLTAGE TEST (SPARE)NOTETests 2, 3, 4, and 5 MUST beperformed in sequence.52. Perform steps 1 thru 40. Check initial control andvalve settings in steps 22 and 23.53. Set hydraulic unit controls as follows:a. ILCA PRESS SYS 1 valve (1) to VENT.b. ILCA PRESS SYS 2 valve (2) to VENT.c. SAS PRESS SYS 1 valve (3) to VENT.d. SAS PRESS SYS 2 valve (4) to VENT.e. RETURN SYS 1 valve (5) to RETURN.f. RETURN SYS 2 valve (6) to RETURN.54. Set electrical unit controls as follows:a. SAS 1 & SAS 2 FUNCTION SELECT switch(30 & 31) to BALANCE.b. SAS 1 & SAS 2 FEEDBACK SELECT switch(32 & 33) to CROSS.c. SAS 1 & SAS 2 LINK TEST switch (38 & 39)to CROSS FDBK.d. SYSTEM SELECT switch (43) to SAS 1.55. DVM (58). Reading shall not exceed 0.0180volts. Record reading.NOTEReading must be recorded. Thisreading is needed for other tests.If reading is greater than 0.0180volts, extensible link cross feedbacktransducer requires adjustment (Task7-100). Repeat Tests 2, 3, and 4.55.1. Set electrical and hydraulic unit controls asfollows:a. SAS 1 FUNCTION SELECT switch (30) toCLSD LOOP.b. RETURN SHUTOFF valve (47) to FULLOPEN.c. SOLENOID valve (53) to OPEN.d. SOLENOID SHUTOFF switch (44) toOPENED.e. Slowly turn HIGH PRESS REGULATORvalve (52) toward INCREASE until HIGHPRESS gauge (13) indicates 1500 psi.7-416 Change 1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business