TM 55-1520-240-23-6
7-98
TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR
(ILCA) (AVIM) (Continued)
7-98
NOTE
If reading is greater than 0.0180 volts,
No. 1 extensible link self feedback
transducer requires adjustment
(Task 7-101). Repeat Test 2 after
adjustments.
46.
Set up hydraulic unit controls as follows:
a.
ILCA PRESS SYS 1 valve (1) to OFF.
b.
ILCA PRESS SYS 2 valve (2) to OFF.
c.
SAS PRESS SYS 1 valve (3) to OFF.
d.
SAS PRESS SYS 2 valve (4) to OFF.
e.
RETURN SYS 1 valve (5) to OFF.
f.
RETURN SYS 2 valve (6) to OFF.
END NO. 1 EXTENSIBLE LINK SELF FEEDBACK
TRANSDUCER NULL VOLTAGE TEST (SPARE)
FOLLOW-ON MAINTENANCE:
Test 3: No. 2 Extensible Link Self Feedback
Transducer Null Voltage Test (Spare).
Change 1