TM 55-1520-240-23-6
7-98
TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR
(ILCA) (AVIM) (Continued)
7-98
51.
Set hydraulic unit controls as follows:
a.
ILCA PRESS SYS 1 valve (1) to OFF.
b.
ILCA PRESS SYS 2 valve (2) to OFF.
c.
SAS PRESS SYS 1 valve (3) to OFF.
d.
SAS PRESS SYS 2 valve (4) to OFF.
e.
RETURN SYS 1 valve (5) to OFF.
f.
RETURN SYS 2 valve (6) to OFF.
END NO. 2 EXTENSIBLE LINK SELF FEEDBACK
TRANSDUCER NULL VOLTAGE TEST
FOLLOW-ON MAINTENANCE:
Test 4: Extensible Link Cross Feedback Transducer
Null Voltage Test.
Change 1
7-415