TM 55-1520-240-23-6
7-72
INSTALL NO. 1 OR NO. 2 POWER TRANSFER UNIT PUMP
(Continued)
7-72
4.
Position pump (5) on bracket (7). Install four
screws (8), washers (9), and nuts (10). Torque
nuts to 85 inch-pounds.
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-310