TM 55-1520-240-23-6
7-75
INSTALL POWER TRANSFER UNIT MOTOR SHAFT SEAL (570973) (AVIM)
7-75
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Feeler Gage
Spanner Wrench (APP E-30)
Torque Wrench, 100 to 750 Inch-Pounds
Soft Jawed Vise
Wood Dowel, 7/8 Inch X 6 Inches
Retaining Ring Pliers
Materials:
Dry Cleaning Solvent (E162)
Gloves (E186)
Cloth (E120)
Parts:
Packings
Seal
Retainer Clip Ring
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
References:
TM 55-1520-240-23P
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1.
Clean metal parts (1 thru 9). Use dry cleaning
solvent (E162). Dry parts with cloth (E120). Use
goggles for eyes. Use gloves (E186).
INSPECT
2.
Install motor (1) in vise (10).
7-315