TM 55-1520-240-23-6
7-46
INSTALL NO. 1 OR NO. 2 POWER CONTROL MODULE PRESSURE
TRANSDUCER
(Continued)
7-46
NOTE
There are two pressure transmitters,
one in No. 1 and one in No. 2 module.
Procedure is same to install any
pressure transmitter. No. 1 module is
shown here.
1.
Install transmitter (1) and packing (2) in PRESS
XMTR port (3).
2.
Lockwire transmitter (1) to pressure switch (4).
Use lockwire (E231).
3.
Connect connector (5) to transmitter (1).
INSPECT
FOLLOW-ON MAINTENANCE:
Service flight control system (Task 1-62 or 1-63).
Perform operational check (TM 55-1520-240-T).
Close right forward work platform or install aft pylon
access door (Task 2-2).
END OF TASK
7-223