TM 55-1520-240-23-6
7-40.1
REMOVE NO. 1 OR NO. 2 POWER CONTROL MODULE HIGH PRESSURE CHECK
VALVE
(Continued)
7-40.1
4.
Remove lockwire from valve (6).
5.
Remove valve (6) from module (5). Use cloths
(E135) for spilled fluid. Wear gloves (E184.1).
6.
Remove two back-up rings (7), and packing (8)
from valve (6).
7.
Remove two retainers (9), and packing (9.1) from
valve (6).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-206