TM 55-1520-240-23-6
7-40
INSTALL NO. 1 OR NO. 2 POWER CONTROL MODULE HIGH PRESSURE RELIEF
VALVE
(Continued)
7-40
TO INSTALL RELIEF VALVE IN NO. 1 MODULE
1.
Install packing (1), two retainers (2), and packing
(3) on valve (4).
2.
Install valve (4) in module (5) by turning nut (6).
3.
Lockwire valve (4). Use lockwire (E231).
INSPECT
7-201