TM 55-1520-240-23-6
7-39
REMOVE NO. 1 OR NO. 2 POWER CONTROL MODULE HIGH PRESSURE RELIEF
VALVE
(Continued)
7-39
4.
Remove lockwire from valve (6).
5.
Remove valve (6) from module (5) by turning nut
(7). Use cloths (E135) for spilled fluid.
6.
Remove two retainers (8) and two packings (9)
from valve (6).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-199