TM 55-1520-240-23-6
7-326
FLUSH CARGO DOOR MOTOR TUBING
(Continued)
7-326
17.
Working through cargo ramp panel, disconnect
hose (6) from tube (7) and tee (3). Use cloths
(E120) for spilled fluid. Use gloves (E186).
18.
Disconnect hose (4) from tube (5) and tee (3).
Use cloths (E120) for spilled fluid.
19.
Disconnect hose (1) from tube (2) and tee (3).
Use cloths (E120) for spilled fluid.
FOLLOW-ON MAINTENANCE:
Install cargo door motor (Task 7-289).
Perform operational check of cargo door (TM
55-1520-240-T).
Install ramp panel (Task 2-249).
END OF TASK
7-1196