TM 55-1520-240-23-6
7-325
FLUSH RAMP CONTROL PRESSURE TUBING
(Continued)
7-325
33.
Disconnect hose (43) from tee (42) at left ramp
actuator (39). Use container and cloths (E120)
for spilled fluid. Use gloves (E186).
34.
Disconnect two hose (41 and 38) from tee (42).
35.
Disconnect three hoses (41, 36 and 37) from tee
(40).
36.
Connect RAMP UP hose (38) to lower port (49)
of actuator (39). Remove tag.
37.
Connect RAMP DOWN hose (37) to middle port
(50) of actuator (39). Remove tag.
38.
Connect RAMP UNLOCK hose (36) to top port
(51) of actuator (39). Remove tag.
INSPECT
39.
Disconnect hose (32) from hose (34) at right
ramp actuator (30).
40.
Connect RAMP UP hose (34) to lower port (35)
of actuator (30). Remove tag.
41.
Connect RAMP DOWN hose (32) to middle port
(33) of actuator (30). Remove tag.
42.
Remove plug (31) from hose (28).
43.
Connect RAMP UNLOCK hose (28) to top port
(29) of actuator (30). Remove tag.
INSPECT
44.
Disconnect hose (27) from tubes (22 and 25).
45.
Connect tube (22) to port (23) of valve (24).
46.
Connect tube (25) to port (26) of valve 24).
INSPECT
7-1192