TM 55-1520-240-23-6
7-322
FLUSH WHEEL BRAKE PRESSURE TUBING
7-322
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Hydraulic Test Stand
Filter Assembly Kit ADHT6814-M9716M
Hoses
Container, 2 Quart
Workstand
Materials:
Cloths (E120)
Gloves (E186)
Personnel Required:
Aircraft Pneudraulics Repairer (2)
Inspector
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Utility Hydraulic System Depressurized (Task 7-135.1)
Right and Left Aft Landing Gear Access Panels Open
(Task 2-2)
Ramp Open and Level (TM 55-1520-240-T)
Forward Left Work Platform Open (Task 2-2)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-1164