TM 55-1520-240-23-5
6-99
INSTALL ENGINE TRANSMISSION OUTPUT SHAFT OIL SEAL
(Continued)
6-99
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1.
Clean seal retainer (1). Use dry cleaning solvent
(E162) and cloths (E120). Wear gloves (E186).
Wear Kevlar gloves (E187) when
handling hot retainer.
Do not heat retainer over 250ºF
(120ºC).
2.
Heat retainer (1) to 230º to 250ºF (110º to
120ºC). Use gun-type heater. Wear Kevlar gloves
(E187). Check temperature with pyrometer.
3.
Install packing (2) in retainer (1).
4.
Install seal (3) in retainer (1), flat side up. Use
aluminum tube.
5.
Install retaining ring (4).
6-379