TM 55-1520-240-23-5
6-81
INSTALL AFT TRANSMISSION SUMP
(Continued)
6-81
4.
Connect connector (11) to chip detector
receptacle (12). Connect connector (13) to
temperature probe receptacle (14).
5.
Install bolts (9), wire clamp plates (15), washers
(6) and nuts (7) at three places at forward and
left edges of sump (2).
6.
Install bolts (9), washers (10 and 6) and nuts (7)
at 13 places around sump (2).
7.
Torque 24 nuts (7) to 60 inch-pounds.
INSPECT
FOLLOW-ON MAINTENANCE:
Service aft transmission (Task 1-54).
Perform ground run (TM 55-1520-240-10).
Install aft transmission drip tray (Task 2-3).
Close baffles under aft transmission (Task 2-2).
Close cargo ramp (Task 2-2).
END OF TASK
6-310